Call UsCall Us : 08045477242
Change Language
VISCOMETER CLEANING AND DRYING APPARATUS
VISCOMETER CLEANING AND DRYING APPARATUS
VISCOMETER CLEANING AND DRYING APPARATUS
VISCOMETER CLEANING AND DRYING APPARATUS

VISCOMETER CLEANING AND DRYING APPARATUS

Price 250000.00 INR/ Piece

MOQ : 1 Piece

VISCOMETER CLEANING AND DRYING APPARATUS Specification

  • Operating Voltage
  • 220V AC
  • Max Height
  • Approximately 60 cm
  • Temperature
  • Ambient to 80C (heating cycle)
  • Test Range
  • Compatible with standard U-tube/Ostwald viscometers
  • Accuracy
  • Depends on viscometer type
  • Port Size
  • 3/8 (inlet/output)
  • Features
  • Simultaneous cleaning and drying, glass chamber
  • Interface Type
  • Manual/valve interface
  • Frequency
  • 50 Hz
  • Mounting Type
  • Benchtop
  • Power Supply
  • 220V AC, 50 Hz
  • Application
  • Cleaning and drying of glass capillary viscometers
  • Response Time
  • Immediate to manual triggers
  • Equipment Type
  • Viscometer Cleaning and Drying Apparatus
  • Specimen Size
  • Standard glass capillary viscometer sizes
  • Automation Grade
  • Semi-Automatic
  • Number of Specimens
  • Up to 6 viscometers simultaneously
  • Display Type
  • No digital display
  • Humidity
  • Up to 90% RH
  • Gas Pressure
  • 0.51 kg/cm (air supply required)
  • Usage
  • Laboratory cleaning apparatus
  • Capacity
  • 6 viscometers
  • Machine Weight
  • Approx. 18 kg
  • Control Mode
  • Manual with toggle controls
  • Air Inlet Connection
  • Standard compressed air line
  • Heating Mechanism
  • Integrated electrical heater for drying
  • Safety Features
  • Pressure regulation, overflow drainage
  • Solvent Tank Capacity
  • Approx. 5 liters
  • Noise Level
  • < 60 dB
  • Drain Valve
  • Yes, corrosion-resistant
  • Cleaning Method
  • Uses solvents and filtered air
  • Window Type
  • Transparent viewing windows
  • Material of Construction
  • Stainless steel and borosilicate glass
 

VISCOMETER CLEANING AND DRYING APPARATUS Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 100 Pieces Per Month
  • Delivery Time
  • 4 Week
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • Wooden Box / Corrugated Box
  • Certifications
  • ISO 9001 : 2001
 

About VISCOMETER CLEANING AND DRYING APPARATUS

Furtherdetails available on our website.

Price and specificationsmentioned here are subject to change as per the application, customerrequirements and prevailing market conditions. Please refer to us for the finalrates and offer.



Efficient Laboratory Cleaning Solution

This apparatus is purpose-built for cleaning and drying glass capillary viscometers, allowing for simultaneous processing of up to six specimens. Combining solvent wash with filtered air drying, it ensures rapid turnaround and consistent cleanliness, key for precise viscometer measurements.


Robust and Safe Construction

Manufactured from stainless steel and borosilicate glass, the unit is designed for durability and chemical resistance. Integrated safety features such as pressure regulation, overflow drainage, and a corrosion-resistant drain valve maintain operational safety during frequent laboratory use.


Simple, Manual Operation

Designed for ease of use, this benchtop device features manual toggle controls and a practical valve interface. No digital display is requiredusers can observe the cleaning process directly via transparent windows, ensuring immediate response and full process control.

FAQs of VISCOMETER CLEANING AND DRYING APPARATUS:


Q: How does the viscometer cleaning and drying apparatus clean and dry viscometers?

A: The apparatus cleans viscometers using solvent circulation followed by filtered air drying. The integrated heater allows drying at temperatures up to 80C, providing rapid and thorough preparation for reuse.

Q: What types and sizes of viscometers are compatible with this equipment?

A: It is compatible with standard glass capillary viscometer sizes, including U-tube and Ostwald types, making it a versatile choice for most laboratory settings.

Q: When should I use this device in the laboratory workflow?

A: Use the apparatus immediately after viscometer usage to prevent sample residue from hardening and to ensure reliable, contaminant-free readings in subsequent tests.

Q: Where can this cleaning apparatus be installed in the lab?

A: Its compact benchtop design allows for easy placement on standard laboratory work surfaces near air and power supply connections.

Q: What is the procedure for operating the cleaning and drying cycle?

A: Simply load up to six viscometers, set the manual toggle controls, ensure solvent and compressed air lines are connected, and initiate the cycle. The process uses solvent wash followed by heated and filtered air drying.

Q: What are the main benefits of using this apparatus for viscometer maintenance?

A: The main benefits include reduced manual handling, faster cleaning cycles, consistent drying, improved safety features, and prolonged viscometer lifespan due to gentle yet effective processes.

Q: How does the apparatus ensure operator safety during cleaning and drying?

A: Safety is ensured through pressure regulation, an overflow drainage system, a corrosion-resistant drain valve, and transparent viewing windows that allow users to monitor the process without exposure to chemicals.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Petroleum Testing Equipments Category

Cleaveland Flash Point Apparatus

Cleaveland Flash Point Apparatus

Price 7000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Operate Method : Electric

Power Supply : 220 Volts, 50 Hz, Single phase, AC Supply

Usage : Laboratory

Features : Accurate results, Robust construction, Efficient working

Reid Vapour Pressure Test Apparatus

Reid Vapour Pressure Test Apparatus

Minimum Order Quantity : 1 , , Piece

Operate Method : Electric

Power Supply : 230 Volts, 50 Hz, Single Phase AC Supply

Usage : Laboratory

Features : Accurate results, Robust construction, Efficient working

Demulsibility Test Apparatus-(Water Separability Test Apparatus)

Demulsibility Test Apparatus-(Water Separability Test Apparatus)

Price 85000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Operate Method : Electric

Power Supply : 220/240 Volts, 50 Hz, Single phase,Ac Supply

Usage : Laboratory

Features : Accurate results, Robust construction, Efficient working

Twin Distillation Apparatus

Twin Distillation Apparatus

Price 180000.00 INR / Piece

Minimum Order Quantity : 1 Piece

Operate Method : Electric

Power Supply : 230 Volts, 50 Hz, Single phase, AC Supply

Usage : Laboratory

Features : Accurate results, Robust construction, Efficient working