Call UsCall Us : 08045477242
Change Language
Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime
Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime
Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime
Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime

Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime

Price 80720 INR/ Unit

MOQ : 1 Piece

Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime Specification

  • Display Type
  • Visual (Graduated burette/volume scale)
  • Interface Type
  • Glass joints
  • Humidity
  • Room Conditions (2080% RH)
  • Usage
  • Cement Testing
  • Automation Grade
  • Manual
  • Accuracy
  • 0.5%
  • Equipment Type
  • Chemical Testing Apparatus
  • Mounting Type
  • Table Top
  • Application
  • Covers method of test for determination of carbon dioxide content of building lime.
  • Number of Specimens
  • 1 at a time
  • Power Supply
  • Not Required (Manual Operation)
  • Max Height
  • 35 cm (Assembled)
  • Resolution
  • 0.1%
  • Specimen Size
  • 510 g lime sample
  • Response Time
  • 1020 minutes (standard procedure)
  • Temperature
  • Room Temperature (2030C)
  • Measuring Range
  • 020% CO
  • Features
  • Corrosion-resistant glassware, easy cleaning, chemical compatibility
  • Test Range
  • 020% CO determination in lime
  • Operating Voltage
  • N/A (manual operation)
  • Port Size
  • Standard Glassware fittings (Borosilicate glass joints)
  • Gas Pressure
  • Ambient
  • Capacity
  • Single test per operation
  • Machine Weight
  • 8.5 kg
  • Test Speed
  • Manual
  • Control Mode
  • Manual
 

Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • FOB Port
  • Ahmedabad
  • Supply Ability
  • 100 Pieces, , Per Month
  • Delivery Time
  • 8 Week
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • Wooden Box / Corrugated Box
  • Main Export Market(s)
  • Australia, South America, Middle East, Africa, Asia
  • Main Domestic Market
  • All India
  • Certifications
  • ISO 9001 : 2015
 

About Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime

Covers method of test for determination of carbon dioxide content of building lime.

Details:

The system consists of a U tube A with anhydrous granulated calcium chloride and another U tube B with soda asbestos, funnel C with a glass stopcock S and a bent inlet glass tube is used to introduce hydrochloric acid into the generating flask D.

Condenser E condenses most of the water and hydrochloric acid. The U tube F contains zinc pallets to react with residual acid, if any acid to absorb moisture. Bubbler G contains concentrated Sulphuric. The U tube Hr contains pumice stone, impregnated with anhydrous copper Sulphate to remove traces of hydrogen Sulphide.

Pumice stone is prepared by crushing it to approximately 5 mm size, shifting it free from dust and then transferring 60 g of it to a casserole, it is then covered with a concentrated solution of 30 to 35 g of copper Sulphate and then evaporated to dryness while stirring constantly.

Furtherdetails available on our website.

The Price mentioned here are subject to change as per the capacity,specifications and application of the user.







Precision Chemical Testing for Building Lime

This apparatus is meticulously crafted to deliver accurate carbon dioxide determination in lime samples. Its manual operation, alongside a clearly graduated burette, enables precise measurement within a 020% range. The robust borosilicate glass construction promotes chemical resistance and long-term reliability. Designed for professional laboratory environments, it meets stringent IS:6932 compliance standards, ensuring credibility in cement quality evaluation.


Easy Operation and Maintenance

Assembling and operating the apparatus is straightforward with manual controls and labelled volume marks. Cleaning is simplified, requiring only laboratory glassware detergent thanks to its corrosion-resistant components. The device is mounted on a stable table-top stand, facilitating safe handling and consistent results. Protective foam and carton packaging ensures secure transportation and convenient storage.

FAQs of Assembly Of Apparatus For Determination Of Carbon Dioxide in Lime:


Q: How is the Assembly of Apparatus for Determination of Carbon Dioxide in Lime used in laboratory settings?

A: This apparatus is employed for manually determining the CO content in lime by following IS:6932 (Part VII) methods. The process involves preparing a powdered lime sample, assembling the apparatus on its retort stand, and conducting the test at room temperature using graduated volume measurements from the burette.

Q: What are the main components included in this carbon dioxide determination apparatus?

A: The set features a borosilicate glass absorption flask, guard tube, gas absorption vessel, dropper bottle, burette, drying tube, rubber stoppers, and a heavy-duty adjustable retort stand. All components are designed for corrosion resistance and optimal chemical compatibility.

Q: When should I calibrate the burette, and how is this done?

A: Manual calibration is necessary before each test to ensure accuracy. This involves verifying the volume marks visually and adjusting the burettes position if needed, following laboratory practices to maintain 0.5% measurement precision.

Q: Where should the apparatus be stored when not in use?

A: After cleaning, the apparatus should be stored in a dry, dust-free environment to maintain integrity. The supplied protective foam and carton packaging safeguards the components from physical damage and contamination.

Q: What is the recommended method for cleaning the apparatus after use?

A: All glassware parts are washable using laboratory glassware detergents. After cleaning, rinse thoroughly and air dry before storage to prevent chemical residue or water spots.

Q: What benefits does using borosilicate glass construction provide?

A: Borosilicate glass offers excellent resistance to dilute acids and carbonates, minimizes corrosion, and extends the life of the apparatus, making it ideal for repeated laboratory chemical testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Cement Testing Equipment Category

Automatic Compression/Flexural Testing Machine

Automatic Compression/Flexural Testing Machine

Price 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Laboratory / Industrial

Application : Compression and flexural strength testing of concrete specimens

Control Mode : Automatic / PLC Controlled

Wet Sieving Apparatus - (Fly Ash Testing Apparatus)

Wet Sieving Apparatus - (Fly Ash Testing Apparatus)

Price 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Cement Testing Equipment

Application : Used for determining the fineness of fly ash

Product Type : Wet Sieving Apparatus

Control Mode : Manual Switch Operation

Vicat Needle Apparatus

Vicat Needle Apparatus

Price 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Cement Testing Equipment

Application : Setting time and consistency test for cement

Product Type : Vicat Needle Apparatus

Control Mode : Manual

Shrinkage Bar Mould

Shrinkage Bar Mould

Price 1.00 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Cement Testing Equipment

Application : For measurement of drying shrinkage. Length measuring device, reference points of 6.5mm dia and all other accessories required for the drying shrinkage test are to be purchased separately

Product Type : Shrinkage Bar Mould

Control Mode : Manual